Complete Your Order
Contact Us
 
9am - 7pm EST Monday - Friday
10am - 7pm EST Saturday
Please note: trim images are an example of shape and size. Images are not necessarily specific to this particular product. Moldings are not created to be an exact match, but as a complement to the overall color & finish of the floor. Grain and color variation should be expected.

12mm Bel-Air Windwood Laminate Flooring

Visual representation of average product rating from all associated reviews using stars
1 reviews
This product has been discontinued.
Please see comparable products below.

Accessories

Quarter Round
Quarter Round
3/4" x 3/4" x 94"
Covers expansion gap between the floor and the wall
Learn More
$47.99 ea.
$47.99 ea.
T-Molding
T-Molding
2" x 94"
Joins two floors that are the same height
Learn More
$55.99 ea.
$55.99 ea.
Reducer
Reducer
1-1/2" x 94"
Transitions a taller floor to a lower floor
Learn More
$55.99 ea.
$55.99 ea.
End Cap
End Cap
1-1/2" x 94"
Transition hand surfaces to carpet, sliding doors, & more
Learn More
$55.99 ea.
$55.99 ea.
Stairnose
Stairnose
2" x 94"
Absorbs impact & protects your stairs
Learn More
$59.99 ea.
$59.99 ea.
  • Beautiful Acacia wood pattern.
  • Easy to install, clean, and maintain.
  • Low cost alternative to real wood.
  • AC3 rating for residential and commercial uses.
Description - Featuring three different deep rich Acacia colored patterns in a wide plank, our Windwood laminate flooring collection is the perfect low cost flooring option for any home or business. Easy to clean and maintain, these flooring planks are a much more desired flooring option for areas where large amounts of abuse may occur on the floor. Water resistant and AC3 rated, these laminate flooring planks have been built to last and are backed by a 25 year warranty. Windwood laminate flooring can also be installed at, above or below grade making it the perfect alternative to standard engineered or hardwood flooring.
Material – Our laminate floor planks are highly durable and made with multi-layer construction to help ensure resistance to staining, fading, surface moisture and wear.
Size – Laminate floor planks are 6.65" wide x 47.83" long.
Thickness – 12.3mm (~1/2")
Class Rating – AC3 (Designed for home use in all foot traffic areas and can meet some commercial standards)
Weight – Each laminate plank weighs ~5 lbs.
Recommended Uses – Our Windwood Collection laminate flooring is rated Class AC3 making it perfect for both residential and commercial applications. These flooring planks have been used successfully in office lobbies, living rooms, family rooms, basements, half baths, closets, entry ways, home offices, low to medium traffic office areas, dining rooms, kitchens and much more.

In Stock - Ships between Oct 15 - 16

Laminate planks are easy to keep clean and maintain. Maintenance of the floor typically includes the following:
  • Use a damp cloth to blot up spills as soon as they happen. Never allow liquids to stand on your floor.
  • For tough spots, such as oil, paint, markers, lipstick, ink, or tar, use acetone/nail polish remover on a clean white cloth, then wipe the area with a damp cloth to remove any remaining residue.
  • Sweep, dust, or vacuum the floor regularly with the hard floor attachment to prevent accumulation of dirt and grit that can scratch or dull the floor finish.
  • Periodically clean the floor with cleaning products made specifically for laminate floor care.
  • Do not wash or wet mop the floor with soap, water, oil-soap detergent, or any other liquid cleaning material. This could cause swelling, warping, delamination, and joint-line seperation, and void the warranty.
  • Do not use steel wool, abrasive cleaners, or strong ammoniated or chlorinated type cleaners.
  • Do not use any type of buffing or polishing machine.
  • For spots such as candle wax or chewing gum, harden the spot with ice and then gently scrape with a plastic scraper, such as a credit card. Be careful not to scratch the flooring surface. Wipe clean with a damp cloth.
  • Use felt pads under chair and furniture legs to prevent scratching of the floor surface.
  • Place door mats at all entrances to prevent tracked in dirt, rocks, moisture, and other debris.
General Information:
The flooring is installed as a “floating flooring”. This means that the flooring should not be fixed to the subfloor and there should be 4-6 mm distance to wall and other fixed objects. Remove any flooring strips. Measure the room accurately at a right angle to the direction of the floorboards. The floorboards in the final row should be at least 5 cm wide. If necessary, the floorboards in the first row can be cut to smaller size. Tools needed to install the flooring are a pad saw or fine toothed handsaw and an installation kit containing spacer block and an installation tool. You also need an underlayment (cork, foam or rubber) and in certain cases 0.2 (.008 in) mm plastic film for insulation against moisture.
Flooring Prep:
Store the floorboards at room temperature for at least 48 hours still in their packaging, prior to commencing work. The room temperature must be at least 18°C (65°F) before and during installation. Floor areas more than 100 m² (900 sq. ft.) with dimensions greater than 10 m (30 feet) in either length or with, in transitions between two rooms and asymmetrical floor areas requires expansion gaps in the floor installation.
Subfloor Prep:
The flooring can be laid on top of most hard surfaces such as resilient floor coverings, wood flooring and ceramic tile. Soft subfloors such as carpets and similar must be removed. The subfloor must be even, flat, dry and variations should not exceed +/- 2 mm in 2 m (.08 in 6.6'). On wooden floors the flooring is normally laid across the existing floorboard.
All type of concrete, wooden and ceramic surfaces must be completely dry:
  • For wood surfaces, moisture rate corresponding to 50% RAH
  • For concrete screeds CM < 2.0%/
  • For anhydride screeds CM < 0.5%

All types of concrete and ceramic subfloors require insulation against damp. This is also required for concrete floors with built-in-moisture barrier or heating and concrete floors with resilient floor covering. Use moisture barrier film with a minimum thickness of 0,2mm (.008) and allow for at least 20cm (8”) overlapping before taping. Turn the film upwards along the walls and trim when the laying of the floor is completed. Underlayment must be used over the entire installation when installing. Use underlayment paper or foam with a thickness of 3mm (.12 in).
Heated Floor Prep:
Follow the instructions for the subfloor heating systems supplied by the manufacturer/contractor. Also note the following: Turn the subfloor heating off for 2 – 3 days so that the floor is room temperature prior to laying. The surface temperature of the floor must not exceed 28°C (82°F) and the maximum output from the heating cables must not exceed 60 W/m². Make sure that the floor surface has no hot and cold areas, as this will cause tension in the floor when the heating cables are in use. Turn on the heating system after laying is completed. We recommend following start up procedure: During the first week, the heating should be set to low or medium for 2 hours per day. During the next week, set the heating to medium output, 24 hours per day. After the initial period, the heating can be regulated in a normal way. Note: That when using carpets, the surface temperature of the flooring might be higher than recommended.
Installation:
  • Begin laying the flooring in the left-hand corner. Place the floorboard 4-6mm from the left wall. The distance to the wall in front (4-6mm) is not important because the flooring can be pushed into place at a later stage.
  • Press the end section of the next floorboard at an angle to the first one, then lay down. Complete the first row in the same manner.
  • Place the final floorboard face down and the short side without the locking strip towards the wall. The distance to the wall should be 4-6mm. Mark where the floorboard is to be cut.
  • Place the floorboard face down on the work surface and cut to size using a pad under 1 saw. Use a fine toothed type if you are using a hand saw. In this case, cut the floorboards face up.
  • Use a cut piece of floorboard from the previous row to start the next row. This must be at least 30 cm long. If the piece is too short, start with a new board and cut in half. Always ensure that the end joints are staggered at least 30 cm.
  • Place the floorboard at an angle against the floorboard in the previous row, press forward and fold down at the same time.
  • Place the next floorboard at an angle against the previous installed floorboard and push it against the row in front. Put it down when the floorboards are positioned tightly.
  • The distance to the walls can be adjusted when the three rows are completed. Place the flooring 4-6mm from the walls.
For printable warranty information, please Click Here.
Don't see what you're looking for? 
are these interlocking
ang
Yes, Bel-Air Windwood laminate flooring is made with a tongue-and-groove design that locks into place for easy floating installations.
No results found.
prev page 1 ... ... next page
prev page PREV
prev page PREV
NEXT next page
NEXT next page
Average Rating
Visual representation of average product rating from all associated reviews using stars
5.0/5.0

Visual representation of product rating from review using stars
  Great product
Anonymous from Mississippi wrote...
Had a great experience working with Holly. Love this floor!
All Review Images icon View all customer images
Your item was added to the cart
Color:
Qty:
$0.00 total