Infection-Control Considerations During Installation

The install decides where liquid and soil can collect for the life of the floor. Plan the wall joint, the seams and the edges first.

Key takeaways

  • Close the floor-to-wall joint with a coved base
  • Do not leave a loose or taped edge in a wet zone
  • Ventilate new rubber and wait a few days before patients use the room
  • Confirm disinfectant compatibility with the manufacturer
Every open joint you leave at install is a place for mop water to collect.

Close the floor-to-wall joint

The floor-to-wall junction is where mop water collects. A coved sanitary base closes that joint. Duracove 2.5" rubber wall base is FloorScore certified and comes in 120-foot rolls. Many architects specify a six-inch cove. In that case, use the Duracove 6" base.

Choose the seam detail for each room

  • Welded: Fuses two pieces into one. Use it for surgical and sterile prep rooms, with a heat-welding specialist.
  • Sealed: Seam sealer closes the joint against water at the surface. It does not fuse the pieces.
  • Fully adhered: Full-spread adhesive holds seams and edges where wheels roll.
  • Loose or taped: Do not use it in a wet zone. A loose edge is where liquid gets underneath.

Plan every edge before the install

Rubber expands and contracts with temperature. Without a defined termination, the edges can curl and trap water underneath. Plan the edge treatment before the install. Our rubber floor ramps fit 4–6mm and 7–9mm material only. For thicker rubber, end the floor at a coved wall base.

Need the base and seam parts too?

Send us the room list. We will put the floor, the wall base and the seam parts on one quote.

Ventilate before patients return

New rubber off-gasses. The smell peaks in the first 48 to 72 hours, and more in heat and humidity. Then it fades with ventilation. Unpack rubber in a well-ventilated area. Mop it with a mild soap and water solution, and let it air dry. Wait a few days before patients use the room. If the smell stays past the first month or two, something is wrong with the product or the install. Ask the supplier to investigate.

Clean with chemistry the floor tolerates

Confirm your disinfectant with the floor manufacturer before the first cleaning. Concentration and dwell time matter as much as the chemistry. Our rubber care guidance advises against solvent and oil-based cleaners, and names Pine-Sol and Lysol. Do not power wash an interior floor. The pressure drives water into seams and under edges.

⚠️ Infection-control requirements during construction are set by your facility. Coordinate the work area plan with your infection-prevention team.
HealthcareProject guideInfection controlInstallation